4.7 Article

Facile preparation of hexadecyl-functionalized magnetic core-shell microsphere for the extraction of polychlorinated biphenyls in environmental waters

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 409, Issue 13, Pages 3337-3346

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-017-0278-x

Keywords

Hexadecyl; Magnetic microsphere; Polychlorinated biphenyl; Gas chromatography-tandem mass spectrometry; Water

Funding

  1. National Nature Science Foundation of China [21507116, 41473095]
  2. China Postdoctoral Science Foundation [2015M572213, 2016T90744]
  3. Fundamental Research Funds for the Central Universities, China University of Geosciences (Wuhan) [CUGL160409]

Ask authors/readers for more resources

Alkyl moieties which can retain target analytes due to their lipophilicity are important in sample preparation. In this work, hexadecyl-functionalized magnetic core-shell microspheres (Fe3O4@SiO2-C-16) was successfully prepared by one-pot sol-gel method and used for magnetic solid-phase extraction of polychlorinated biphenyls (PCBs) in environmental water samples. Optimized preparation method was achieved by altering the adding moment of hexadecyl-silane. The resultant materials were systematically characterized by scanning electron microscope, transmission electron microscope, Fourier transform infrared spectroscopy, energy dispersive X-ray spectrometry, tensionmeter, and vibrating sample magnetometer. The results demonstrated that the optimized adsorbent exhibited core-shell structure, superparamagnetic (66 emu/g), and extremely hydrophobic (water contact angle of 122 degrees) properties. To evaluate the extraction performance, the prepared material coupled with gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) was applied to determinate PCBs. The extraction conditions were optimized. Under the optimal conditions, the proposed method showed a good linearity range of 1-100 ng L-1 with correlation coefficients (R) of 0.9989-0.9993. Based on a signal-to-noise ratio of 3 and 10, the limits of detection (LODs) and limits of quantification (LOQs) were in the range 0.14-0.27 and 0.39-0.91 ng L-1, respectively. The intra- and inter-day relative standard deviations (RSDs) were less than 9.06%. The absolute recoveries of PCBs in spiked real water samples were in the range of 75.17 to 101.20%. Additionally, reusability and batch-to-batch reproducibility of the resultant material were acceptable with RSDs less than 5.64 and 3.25%, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available