4.7 Article

A comparative study of ozonation, iron coated zeolite catalyzed ozonation and granular activated carbon catalyzed ozonation of humic acid

Journal

CHEMOSPHERE
Volume 174, Issue -, Pages 218-231

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2017.01.106

Keywords

Humic acid; Ozone; Catalytic ozonation; Iron coated zeolite; Granular activated carbon

Funding

  1. Scientific Research Project of the Ondokuz Mayis University, Samsun, Turkey [PYO. MUH -1901.11,006]

Ask authors/readers for more resources

This study compares ozonation (O-3), iron coated zeolite catalyzed ozonation (ICZ-O-3) and granular activated carbon catalyzed ozonation (GAC-O-3) for removal of humic acid from an aqueous solution. The results were evaluated by the removal of DOC that specifies organic matter, UV254 absorbance, SUVA (Specific Ultraviolet Absorbance at 254 nm) and absorbance at 436 nm. When ozonation was used alone, DOC removal was 21.4% at an ozone concentration of 10 mg/L, pH 6.50 and oxidation time of 60 min. The results showed that the use of ICZ or GAC as a catalyst increased the decomposition of humic acid compared to ozonation alone. DOC removal efficiencies were 62% and 48.1% at pH 6.5, at a catalyst loading of 0.75 g/L, and oxidation time of 60 min for ICZ and GAC, respectively. The oxidation experiments were also carried out using <100 kDa and <50 kDa molecular size fractions of humic acid in the presence of ICZ or GAC. Catalytic ozonation also yielded better DOC and UV254 reduction in both <50 kDa and <100 kDa fractions of HA compared to ozonation. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available