4.8 Article

Signal-On Photoelectrochemical Immunoassay for Aflatoxin B1 Based on Enzymatic Product-Etching MnO2 Nanosheets for Dissociation of Carbon Dots

Journal

ANALYTICAL CHEMISTRY
Volume 89, Issue 10, Pages 5637-5645

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.7b00942

Keywords

-

Funding

  1. National Natural Science Foundation of China [21475025, 21675029]
  2. National Science Foundation of Fujian Province [2014J07001]
  3. Program for Changjiang Scholars and Innovative Research Team in University [IRT15R11]
  4. Alexander von Humboldt Foundation of Germany

Ask authors/readers for more resources

Aflatoxin B-1 (AFB(1)) monitoring has attracted extensive attention because food safety is a worldwide public health problem. Herein, we design a novel simultaneously visual and photoelectrochemical (PEC) immunosensing system for rapid sensitive detection of AFB(1) in foodstuff The immunoreaction was carried out on anti-AFB, antibody-modified magnetic beads by using glucose oxidase (GOX)-labeled AFB(1-)bovine serum albumin (AFB(1)-BSA) conjugates as the tags with a competitive-type immunoassay format, while the visual and PEC evaluation was performed via carbon quantum dots (CQDs)-functionalized MnO2 nanosheets. Accompanying, the formation of immunocomplexes, the carried GOx initially oxidized the substrate (glucose) for the generation of H2O2, which reduced/etched MnO2 nanosheets into Mn2+-ions, thereby resulting in the dissociation of CQDs from the electrode. Within the applied potentials, the photocurrent of MnO(2-)CQDs-modified electrode decreased with the increasing H2O2 level in the detection cell. Meanwhile, a visual detection could be performed according to the change in the color of MnO2-CQDs-coated electrode. To elaborate, this system was aggregated into a high -throughput microfluidic device to construct a semiautomatic detection cell. Under optimal conditions, the photocurrent increased with the increasing target AFB1 within a dynamic working range from 0.01 to 20 ng mL(-1) with a limit of detection (LOD) of 2.1 pg mL(-1) (ppt). The developed immunoassay exhibited good reproducibility and acceptable accuracy. In addition, the method accuracy relative to AFB1 ELISA kit was evaluated for analyzing naturally contaminated or spiked peanut samples, giving the well-matched results between two methods. Although our strategy-was focused on the detection of target AFB1, it is easily extended to screen other small molecules or mycotoxins, thereby representing a versatile immunosensing scheme.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available