4.7 Article

Performance analysis of a novel liquid desiccant evaporative cooling fresh air conditioning system with solution recirculation

Journal

BUILDING AND ENVIRONMENT
Volume 117, Issue -, Pages 218-229

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2017.03.015

Keywords

Dehumidification; Evaporative cooling; Liquid desiccant; Recirculation; Air conditioning

Funding

  1. Natural Science Foundation of China [51376043]
  2. National Key R&D Program of China [2016YFC0700305]
  3. Foundation for Distinguished Young Scientists of Jiangsu Province [BK20140026, BK20151549]

Ask authors/readers for more resources

Liquid desiccant evaporative cooling air-conditioning (LDECAC) system, which combines both advantages of liquid desiccant and evaporative cooling technology, has a great potential to utilize low-grade heat for refrigeration and air conditioning. A novel LDECAC system is proposed to obtain lower supply air temperature and humidity ratio at the expense of less thermal energy consumption when used as a dedicated fresh air system. It consists of a liquid desiccant system with self-cycle solution at dehumidification and regeneration sides, a regenerative indirect evaporative cooler (RIDEC) and a direct evaporative cooler with adjustable by-pass flow. A parametric study on steady-state thermal performance of LDECAC system was performed based on the developed mathematical model. The performance was investigated by varying five key parameters: solution self-cycle ratio (R-s), working to intake air flow ratio (R-a), regeneration temperature, ambient air temperature and humidity ratio. The results show that the system can handle the process air to 17.9 degrees C and 9.2 g/kg with the thermal coefficient of performance of 0.56 under the design condition. The recommended value for R-s lies between 0.6 and 0.7 and that for R-a is 0.2 under the typical operating condition. The variable Rs control method is effective in response to the change of ambient air conditions. Performance comparison with the conventional LDECAC system shows that the novel system can utilize lower temperature heat source and achieve a higher thermal coefficient of performance. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available