3.8 Proceedings Paper

Performance Assessment of a Near Room Temperature Magnetic Cooling System

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.egypro.2016.12.168

Keywords

Clean energy; gadolinium; heating-cooling; magnetic; magnetocaloric

Funding

  1. The Scientific and Technological Research Council of Turkey (TUBITAK) [114M829]

Ask authors/readers for more resources

In this study, performance of a near room temperature magnetic cooling system was investigated experimentally in terms of temperature span. The current setup has a permanent magnet pairs (0.7 Tesla), a magnetocaloric material (Gadolinium) and a heat transfer fluid (water, ethylene glycol and 10% ethanol-water mixing) furthermore solar energy was used as a power source of liner motion of the magnetic system. The obtained results showed that ethanol-water was the best heat transfer fluid and also that optimum magnetization-demagnetization period for the system was found 10 s. (C) 2016 The Authors. Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available