4.8 Article

Engineering of Heterojunction-Mediated Biointerface for Photoelectrochemical Aptasensing: Case of Direct Z-Scheme CdTe-Bi2S3 Heterojunction with Improved Visible-Light-Driven Photoelectrical Conversion Efficiency

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 9, Issue 21, Pages 18369-18376

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.7b04310

Keywords

Z-scheme heterojunction; CdTe quantum dot; Bi2S3 nanorod; photoelectrochemical aptasensor; microcystin-LR detection

Funding

  1. National Natural Science Foundation of China [21375050, 21405063, 21505055, 61601204]
  2. Provincial Natural Science Foundation of Jiangsu [BK20160542]
  3. China Postdoctoral Science Foundation [2015M581745, 2015T80517]
  4. Jiangsu Province Postdoctoral Science Foundation [1601204C]

Ask authors/readers for more resources

This work presents a heterojunction-mediated photoelectrochemical (PEC) biointerface for selective detection of microcystin-LR (MC, LR) by introducing a direct Z-scheme heterojunction as efficient visible-light driven photoactive species. Specifically, the Z-scheme type CdTe-Bi2S3 heterojunction, was designed and synthesized as an ideal photoactive material, which exhibited higher PEC activity as compared with either CdTe quantum clots or Bi2S3 nanorods due to the improved photogenerated charges separation efficiency of heterojunction. Then the MC-LR aptamer was employed for selective recognition of MC-LR target, which was immobilized on the CdTe-Bi2S3 film-by the formation of phosphor-amidate bonds between the phosphate-group of aptamer and amino group of the chitosan film on the electrode.. The proposed aptasensor showed a photocurrent signal due to the photoactive CdTe-Bi2S3 heterojunction, while the presence of MC-LR resulted in a dose-responsive decrease in PEC response, which allowed the quantification analysis of MC-LR by measuring the photocurrent signal of the fabricated aptasensor. Under optimal conditions, the resulted PEC aptasensor showed wide linear range (0.01-100 pM) and low detection limit, (0.005 pm). for MC-LR determination with high selectivity and acceptable reproducibility. Finally, the proposed aptasensing method. was successfully applied in MC-LR detection in real water samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available