4.7 Article

Molecularly imprinted polymers based stir bar sorptive extraction for determination of cefaclor and cefalexin in environmental water

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 409, Issue 17, Pages 4157-4166

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-017-0365-z

Keywords

Molecularly imprinted polymers; Magnetic carbon nanotubes; Cephalosporins; Environmental water; Stir bar sorption microextraction

Funding

  1. Chinese College Students Innovation Project for the R&D of Novel Drugs [J1310032]
  2. Jiangsu Province Environmental Protection Scientific Research Subject and Science and Technology Project-Nanotechnology Special of Suzhou Municipal Science and Technology Bureau [ZX201441]

Ask authors/readers for more resources

Although stir bar sportive extraction was thought to be a highly efficiency and simple pretreatment approach, its wide application was limited by low selectivity, short service life, and relatively high cost. In order to improve the performance of the stir bar, molecular imprinted polymers and magnetic carbon nanotubes were combined in the present study. In addition, two monomers were utilized to intensify the selectivity of molecularly imprinted polymers. Fourier transform infrared spectroscopy, scanning electron microscopy, and selectivity experiments showed that the molecularly imprinted polymeric stir bar was successfully prepared. Then micro-extraction based on the obtained stir bar was coupled with HPLC for determination of trace cefaclor and cefalexin in environmental water. This approach had the advantages of stir bar sportive extraction, high selectivity of molecular imprinted polymers, and high sorption efficiency of carbon nanotubes. To utilize this pretreatment approach, pH, extraction time, stirring speed, elution solvent, and elution time were optimized. The LOD and LOQ of cefaclor were found to be 3.5 ng center dot mL(-1) and 12.0 ng center dot mL(-1), respectively; the LOD and LOQ of cefalexin were found to be 3.0 ng center dot mL(-1) and 10.0 ng center dot mL(-1), respectively. The recoveries of cefaclor and cefalexin were 86.5 similar to 98.6%. The within-run precision and between-run precision were acceptable (relative standard deviation < 7%). Even when utilized in more than 14 cycles, the performance of the stir bar did not decrease dramatically. This demonstrated that the molecularly imprinted polymeric stir bar based micro-extraction was a convenient, efficient, low-cost, and a specific method for enrichment of cefaclor and cefalexin in environmental samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available