4.6 Article

Nanoporous and wrinkled electrodes enhance the sensitivity of glucose biosensors

Journal

ELECTROCHIMICA ACTA
Volume 242, Issue -, Pages 1-9

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2017.04.108

Keywords

Electrochemical Biosensing; Wrinkling; Glucose Sensing; Nanoporous Electrodes; Rapid Prototyping

Funding

  1. Natural Sciences and Engineering Council of Canada (NSERC)
  2. Ontario Ministry of Research and Innovation
  3. Ontario Graduate Scholarship
  4. NSERC
  5. McMaster University

Ask authors/readers for more resources

Three-dimensional electrodes improve the performance of biosensors by increasing their surface area to volume ratio, decreasing the analyte diffusion time, and/or improving analyte access or capture at the electrode. We demonstrate a rapid and facile method based on electroless deposition and polymer-induced wrinkling for creating three-dimensional multi-lengthscale electrodes. This all solution-processing method enables the structure of the electrodes to be tuned by inducing continuous or nanoporous wrinkled surfaces. The surface area and analytical sensitivity of the electrodes are tuned by varying the electroless deposition duration, with the nanoporous and wrinkled electrodes demonstrating the highest surface area and analytical sensitivity compared to their wrinkled and planar counterparts. The nanoporous and wrinkled electrodes developed here combine critical lengthscales ranging from the nanoscale to the macroscale by including nanoscale pores, microscale wrinkles and sub-millimetre-scale electrode footprints, and demonstrate a surface area enhancement of more than 5 times compared to the all-solution-processed planar electrodes. These electrodes were applied to glucose sensing, and their response was measured using three classes of electrochemical techniques: cyclic voltammetry, chronoamperometry, and pulsed amperometric detection. When using cyclic voltammetry, these electrodes enable enzyme-free glucose sensing with a sensitivity of 591 mu A/mM.cm(2) in alkaline solutions. This sensitivity is preserved when analysing solutions having a physiologically-relevant concentration of Cl ions, and is reduced to 38 mu A/mM.cm(2) when analysing solutions having a neutral pH. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available