4.2 Article

Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions

Journal

JOURNAL OF CLINICAL MONITORING AND COMPUTING
Volume 32, Issue 3, Pages 447-455

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s10877-017-0030-2

Keywords

Photoplethysmography; Vascular occlusions; Near infrared spectroscopy; Blood volumes; Oxygenation

Categories

Funding

  1. Barts and The London NHS Trust under Barts Charity Grant [832/1716]

Ask authors/readers for more resources

Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO(2)) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO2 for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated (Delta HbO(2)), reduced (Delta HHb) and total haemoglobin (Delta tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A(Ox) = Delta A(IR) - Delta A(R)) and by the conventional SpO(2). The Delta HbO(2), Delta HHb, Delta tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Alt-man analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A Ox indicated significant changes for occlusion pressures exceeding 20 mmHg (p < 0.05) and correlation with tissue oxygenation changes measured by NIRS, while SpO(2) had significant changes after 40 mmHg (p < 0.05). Relative changes in haemoglobin concentrations can be estimated from PPG signals and they showed a good level of accuracy in the detection of perfusion and oxygenation changes induced by different degrees of intermittent vascular occlusions. These results can open up to new applications of the PPG waveform in the detection of blood volumes and oxygenation changes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available