4.2 Article

Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement

Journal

JOURNAL OF CLINICAL MONITORING AND COMPUTING
Volume 32, Issue 1, Pages 13-22

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s10877-017-9984-3

Keywords

Blood pressure monitors; Arterial pressure; Monitoring, intraoperative

Categories

Funding

  1. Finnish Cultural Foundation
  2. Pirkanmaa Regional Fund [4/2014]
  3. Finnish Society of Anaesthesiologists
  4. Paulo Foundation [12/2015]

Ask authors/readers for more resources

Intermittent non-invasive blood pressure measurement with tourniquets is slow, can cause nerve and skin damage, and interferes with other measurements. Invasive measurement cannot be safely used in all conditions. Modified arterial tonometry may be an alternative for fast and continuous measurement. Our aim was to compare arterial tonometry sensor (BPro(A (R))) with invasive blood pressure measurement to clarify whether it could be utilized in the postoperative setting. 28 patients who underwent elective surgery requiring arterial cannulation were analyzed. Patients were monitored post-operatively for 2 h with standard invasive monitoring and with a study device comprising an arterial tonometry sensor (BPro(A (R))) added with a three-dimensional accelerometer to investigate the potential impact of movement. Recordings were collected electronically. The results revealed inaccurate readings in method comparison between the devices based on recommendations by Association for the Advancement of Medical Instrumentation (AAMI). On a Bland-Altman plot, the bias and precision between these two methods was 19.8 +/- 16.7 (Limits of agreement - 20.1 to 59.6) mmHg, Spearman correlation coefficient r = 0.61. For diastolic pressure, the difference was 4.8 +/- 7.7 (LoA - 14.1 to 23.6) mmHg (r = 0.72), and for mean arterial pressure it was 11.18 +/- 11.1 (LoA - 12.1 to 34.2) mmHg (r = 0.642). Our study revealed inaccurate agreement (AAMI) between the two methods when measuring systolic and mean blood pressures during post-operative care. The readings for diastolic pressures were inside the limits recommended by AAMI. Movement increased the failure rate significantly (p < 0.001). Thus, arterial tonometry is not an appropriate replacement for invasive blood pressure measurement in these patients.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available