4.0 Article

Endovascular treatment of wide-neck intracranial bifurcation aneurysms with 'Y'-configuration, double Neuroform® stents-assisted coiling technique: Experience in a single center

Journal

INTERVENTIONAL NEURORADIOLOGY
Volume 23, Issue 4, Pages 362-370

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/1591019917708568

Keywords

Intracranial aneurysm; bifurcation aneurysm; intracranial stent; Neuroform; 'Y' stenting; 'Y'-configuration stenting; coils

Ask authors/readers for more resources

Background: Intracranial wide-neck aneurysms at the arterial bifurcations, especially in the aneurysms where the bifurcating branches emanate directly from the base of the aneurysm, have been particularly difficult on which to perform endovascular treatment. The 'Y'-configuration, double stent-assisted coil embolization is an option for the treatment of these difficult aneurysms, allowing the closure of the aneurysm, preserving the parent arteries. Material and methods: In a nine-year period, 546 intracranial aneurysms in 493 patients were treated at our center by endovascular approach. We have reviewed the medical records and arteriographies from November 2007 to January 2017 of 45 patients who were treated using 'Y'-configuration double Neuroform (R) stent-assisted coil embolization. Results: All patients were successfully treated. The location of the aneurysms were: middle cerebral artery (MCA) 20 (44.4%), anterior communicating artery (AComA) 17 (37.7%), basilar four (8.9%), internal carotid artery (ICA) bifurcation three (6.6%) and posterior communicating artery (PComA) one (2.2%). The mRS at hospital discharge was: mRS 0: 42 (93.3%), mRS 1: 1 (2.2%), mRS 2: 1 (2.2%) and mRS 5: 1 (2.2%). The Modified Raymond-Roy Occlusion Classification, in the control at six months, was: Class I: 41 (91.1%), Class II: 2 (4.4%), Class IIIa: 1 (2.2%) and Class IIIb: 1 (2.2%). Forty-four (97.8%) patients had a good outcome (mRS < 2) at six months. One (2.2%) patient had a poor outcome (mRS > 2) at six months that was due to sequelae of SAH. There was no mortality at six months. Conclusions: This technique is safe and effective for the endovascular treatment of difficult wide-neck bifurcation aneurysms, allowing the stable closure of the aneurysm, preserving the parent arteries.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available