4.7 Article

Validation of β-lactam minimum inhibitory concentration predictions for pneumococcal isolates with newly encountered penicillin binding protein (PBP) sequences

Journal

BMC GENOMICS
Volume 18, Issue -, Pages -

Publisher

BMC
DOI: 10.1186/s12864-017-4017-7

Keywords

Streptococcus Pneumoniae; beta-lactam antibiotics; Minimum inhibitory concentration (MIC); Penicillin binding protein typing (PBP typing); Predictive modeling

Funding

  1. CDC's Advanced Molecular Detection (AMD) initiative
  2. CDC's Emerging Infection Program

Ask authors/readers for more resources

Background: Genomic sequence-based deduction of antibiotic minimum inhibitory concentration (MIC) has great potential to enhance the speed and sensitivity of antimicrobial susceptibility testing. We previously developed a penicillin-binding protein (PBP) typing system and two methods (Random Forest (RF) and Mode MIC (MM)) that accurately predicted beta-lactam MICs for pneumococcal isolates carrying a characterized PBP sequence type (phenotypic beta-lactam MICs known for at least one isolate of this PBP type). This study evaluates the prediction performance for previously uncharacterized (new) PBP types and the probability of encountering new PBP types, both of which impact the overall prediction accuracy. Results: The MM and RF methods were used to predict MICs of 4309 previously reported pneumococcal isolates in 2 datasets and the results were compared to the known broth microdilution MICs to 6 beta-lactams. Based on a method that specifically evaluated predictions for new PBP types, the RF results were more accurate than MM results for new PBP types and showed percent essential agreement (MICs agree within +/- 1 dilution) >97%, percent category agreement (interpretive results agree) >93%, major discrepancy (sensitive isolate predicted as resistant) rate < 1.2%, and very major discrepancy (resistant isolate predicted as sensitive) rate < 1.4% for all 6 beta-lactams. The identification of new PBP types over time was well approximated by a diminishingly increasing curve (Pearson's r = 0.99) and minimally impacted overall MIC prediction performance. Conclusions: MIC prediction using the RF method could be an accurate alternative of phenotypic susceptibility testing even in the presence of previously uncharacterized PBP types.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available