3.8 Article

In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost

Journal

RADIATION ONCOLOGY JOURNAL
Volume 35, Issue 2, Pages 121-128

Publisher

KOREAN SOC THERAPEUTIC RADIOLOGY & ONCOLOGY
DOI: 10.3857/roj.2017.00150

Keywords

Boost with intraoperative radiotherapy; Segmental mastectomy; Toxicity; In vivo dosimetry

Categories

Funding

  1. KOSRO Young Investigator Fund
  2. new faculty research seed money grant of Yonsei University College of Medicine [2016-32-0018]
  3. Technology Commercialization Program through Innopolis Foundation of Korea-Ministry of Science, ICT and Future Planning [ACC-2016-DDI-00793]
  4. Ministry of Science & ICT (MSIT), Republic of Korea [ACC-2016-DDI-00793] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

Purpose: To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. Materials and Methods: Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A total of 55 patients with a minimum follow-up of 1 month after WBI were evaluated. Optically stimulated luminescence dosimeter (OSLD) detected radiation dose delivered to the skin during IORT. Acute toxicity was recorded according to the Common Terminology Criteria for Adverse Events v4.0. Clinical parameters were correlated with seroma formation and maximum skin dose. Results: Median follow-up after IORT was 25.9 weeks (range, 12.7 to 50.3 weeks). Prior to WBI, only one patient developed acute toxicity. Following WBI, 30 patients experienced grade 1 skin toxicity and three patients had grade 2 skin toxicity. Skin dose during IORT exceeded 5 Gy in two patients: with grade 2 complications around the surgical scar in one patient who received 8.42 Gy. Breast volume on preoperative images (p = 0.001), ratio of applicator diameter and breast volume (p = 0.002), and distance between skin and tumor (p = 0.003) showed significant correlations with maximum skin dose. Conclusions: IORT as a boost was well-tolerated among Korean women without severe acute complication. In vivo dosimetry with OSLD can help ensure safe delivery of IORT as a boost.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available