4.7 Article

Computed Tomography Measure of Lung at Risk and Lung Function Decline in Chronic Obstructive Pulmonary Disease

Journal

Publisher

AMER THORACIC SOC
DOI: 10.1164/rccm.201701-0050OC

Keywords

FEV1; emphysema; image registration; biomechanical; lung at risk

Funding

  1. National Institutes of Health [R01 HL089897, R01 HL089856, R01 HL112986, R01 HL079406, K23HL133438]
  2. COPD Foundation through AstraZeneca
  3. Boehringer Ingelheim
  4. Novartis
  5. Pfizer
  6. Siemens
  7. Sunovion
  8. GlaxoSmithKline

Ask authors/readers for more resources

Rationale: The rate of decline of lung function is greater than age-related change in a substantial proportion of patients with chronic obstructive pulmonary disease, even after smoking cessation. Regions of the lung adjacent to emphysematous areas are subject to abnormal stretch during respiration, and this biomechanical stress likely influences emphysema initiation and progression. Objectives: To assess whether quantifying this penumbra of lung at risk would predict FEV1 decline. Methods: We analyzed paired inspiratory-expiratory computed tomography images at baseline of 680 subjects participating in a large multicenter study (COPDGene) over approximately 5 years. By matching inspiratory and expiratory images voxel by voxel using image registration, we calculated the Jacobian determinant, a measure of local lung expansion and contraction with respiration. We measured the distance between each normal voxel to the nearest emphysematous voxel, and quantified the percentage of normal voxels within each millimeter distance from emphysematous voxels as mechanically affected lung (MAL). Multivariable regression analyses were performed to assess the relationship between the Jacobian determinant, MAL, and FEV1 decline. Measurements and Main Results: The mean (SD) rate of decline in FEV1 was 39.0 (58.6) ml/yr. There was a progressive decrease in the mean Jacobian determinant of both emphysematous and normal voxels with increasing disease stage (P < 0.001). On multivariable analyses, the mean Jacobian determinant of normal voxels within 2 mm of emphysematous voxels (MAL(2)) was significantly associated with FEV1 decline. In mild-moderate disease, for participants at or above the median MAL2 (threshold, 36.9%), the mean decline in FEV1 was 56.4 (68.0) ml/yr versus 43.2 (59.9) ml/yr for those below the median (P = 0.044). Conclusions: Areas of normal-appearing lung are mechanically influenced by emphysematous areas and this lung at risk is associated with lung function decline.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available