4.7 Article

Diagnostic Performance of High Sensitivity Compared with Contemporary Cardiac Troponin I for the Diagnosis of Acute Myocardial Infarction

Journal

CLINICAL CHEMISTRY
Volume 63, Issue 10, Pages 1594-1604

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1373/clinchem.2017.272930

Keywords

-

Funding

  1. Abbott Diagnostics
  2. Minneapolis Medical Research Foundation

Ask authors/readers for more resources

BACKGROUND: We examined the diagnostic performance of high-sensitivity cardiac troponin I (hs-cTnI) vs contemporary cTnI with use of the 99th percentile alone and with a normal electrocardiogram (ECG) to rule out acute myocardial infarction (MI) and serial changes (deltas) to rule in MI. METHODS: We included consecutive patients presenting to a US emergency department with serial cTnI on clinical indication. Diagnostic performance for acute MI, including MI subtypes, and 30-day outcomes were examined. RESULTS: Among 1631 patients, MI was diagnosed in 12.9% using the contemporary cTnI assay and in 10.4% using the hs-cTnI assay. For ruling out MI, contemporary cTnI <99th percentile at 0, 3, and 6 h and a normal ECG had a negative predictive value (NPV) of 99.5% (95% CI, 98.6-100) and a sensitivity of 99.1% (95% CI, 97.4-100) for diagnostic and safety outcomes. Serial hscTnI measurements 99th percentile at 0 and 3 h and a normal ECG had an NPV and sensitivity of 100% (95% CI, 100-100) for diagnostic and safety outcomes. For ruling in MI, contemporary cTnI measurements had specificities of 84.4% (95% CI, 82.5-86.3) at presentation and 78.7% (95% CI, 75.4-82.0) with serial testing at 0, 3, and 6 h, improving to 89.2% (95% CI, 87.1-91.3) by using serial cTnI changes (delta, 0 and 6 h) > 150%. hs-cTnI had specificities of 86.9% (95% CI, 85.1-88.6) at presentation and 85.7% (95% CI, 83.5-87.9) with serial testing at 0 and 3 h, improving to 89.3% (95% CI, 87.3-91.2) using a delta hs-cTnI (0 and 3 h) > 5 ng/L. CONCLUSIONS: hs-cTnI and contemporary cTnI assays are excellent in ruling out MI following recommendations predicated on serial testing and the 99th percentile with a normal ECG. For ruling in MI, deltas improve the specificity. (C) 2017 American Association for Clinical Chemistry

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available