4.7 Article

The effects of higher temperature setpoints during summer on office workers' cognitive load and thermal comfort

Journal

BUILDING AND ENVIRONMENT
Volume 123, Issue -, Pages 176-188

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2017.06.048

Keywords

Higher temperature setpoints; Air-conditioning; Cognitive load; Thermal comfort

Funding

  1. City of Sydney Environmental Performance-Innovation Grant [2016/023775]
  2. University of Sydney [2016/499]
  3. Queensland University of Technology [1600000581]

Ask authors/readers for more resources

Typical commercial lease agreements in Australia stipulate 22.5 +/- 1.5 degrees C in summer as the acceptable thermal condition that buildings have to meet, even though the overcooling incurs excessive and unnecessary energy use, gas emissions and financial expense. An argument that backs up this practice asserts that office workers' productivity and comfort will be jeopardised outside this temperature range. This paper investigated whether the office environments with a practical higher temperature setpoint can still be cognitively efficient and comfortable for office workers. In a controlled climate chamber, 26 office workers experienced the typical summer indoor temperature condition in Australia (22 degrees C) followed by the condition with a higher temperature setpoint (25 degrees C). In both conditions, subjects were required to fulfil Cambridge Brain Science (CBS) cognitive performance tests, NASA Task Load Index (NASA-TLX), and thermal comfort and air quality questionnaires. Meanwhile, participants' electroencephalogram (EEG) and heart rate (HR) were recorded under three different difficulty levels of Paced Auditory Serial Addition Tests (PASAT). Results showed that CBS test scores were not significantly affected by temperature; a higher temperature of 25 degrees C incurred a significantly reduced cognitive load for subjects, as has been observed by NASA-TLX, but probably due to the learning effect; the comparison between EEG and FIR features during different temperatures did not show any significant difference. Participants' thermal comfort was not significantly jeopardized by the 3 degrees C temperature setback either. Results from this study favourably support a practical setback of temperature setpoints in Australian office buildings during summer. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available