4.5 Article

A Fe3O4@Au-basedpseudo-homogeneous electrochemical immunosensor for AFP measurement using AFP antibody-GNPs-HRP as detection probe

Journal

ANALYTICAL BIOCHEMISTRY
Volume 534, Issue -, Pages 56-63

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ab.2017.07.015

Keywords

Electrochemical immunosensor; Fe3O4@Au nanoparticles; Alpha fetoprotein; Horseradish peroxidase; Pseudo-homogeneous reaction system

Funding

  1. National Nature Science Foundation of China [81372362, 81460451, 81430055]
  2. Appropriate Health Technology Development Project of Guangxi Zhuang Autonomous Region [S201422-03]
  3. Post doctoral Research Fund of China [2013T60830, 2013M531916]
  4. National Science Foundation of Guangxi province of China [2015GXNSFDA139025, 2016GXNSFAA380011, 2016GXNSFAA380080]

Ask authors/readers for more resources

In this study, a Fe3O4@Au-based pseudo-homogeneous electrochemical immunosensor was prepared for detection of alpha fetoprotein (AFP), a well-known hepatocellular carcinoma biomarker. The primary antibody (Ab1) was immobilized on Fe3O4@Au NPs as the capture probe. Horseradish peroxidase (HRP) and secondary antibody (Ab2) were conjugated on gold nanoparticles (GNPs) through electrostatic adsorption to form signal-amplifying labels. In the presence of AFP, a sandwich immunocomplex was formed via specific recognition of antigen-antibody in a Fe3O4@Au-basedpseudo-homogeneousreaction system. After the immunocomplex was captured to the surface of magnetic glassy carbon electrode (MGCE), the labeling HRP catalyzed the decomposition of H2O2, resulting in a substantial current for the quantitative detection of AFP. The amperometric (i-t) method was employed to record the response signal of the immunosensor based on the catalysis of the immobilized HRP toward the reduction of H2O2 with hydroquinone (HQ) as the redox mediator. Under the optimal conditions, the amperometric current response presented a linear relationship with AFP concentration over the range of 20 ng/mL-100 ng/mL with a correlation coefficient of 0.9940, and the detection limit was 0.64 ng/mL at signal/noise [S/N] = 3. Moreover, the electrochemical immunosensor exhibited higher anti-interference ability, acceptable reproducibility and long-term stability for AFP detection. (C) 2017 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available