4.6 Article

Selective and sensitive determination of silver ions at trace levels based on ultrasonic-assisted dispersive solid-phase extraction using ion-imprinted polymer nanoparticles

Journal

APPLIED ORGANOMETALLIC CHEMISTRY
Volume 31, Issue 11, Pages -

Publisher

WILEY
DOI: 10.1002/aoc.3758

Keywords

box-Behnken design; ion-imprinted polymer nanoparticles; silver ions; ultrasonic-assisted dispersive solid-phase extraction

Funding

  1. Research Council of Kermanshah University of Medical of Sciences

Ask authors/readers for more resources

We describe ultrasonic-assisted dispersive solid-phase extraction based on ion-imprinted polymer (UA-DSPE-IIP) nanoparticles for the selective extraction of silver ions. Ultrasound is a good and robust method to facilitate the extraction of target ions in the sorption step and elution of the target ions in the desorption step. The IIP nanoparticles used in the UA-DSPE-IIP were prepared by precipitation polymerization. To prepare the IIP nanoparticles, 2-vinylpyridine, ethylene glycol dimethacrylate, 2,2'-azobisisobutyronitrile, 2-picolinic acid, silver and chloroform-methanol (50:50) solution were used as functional monomer, cross-linker, initiator, silver-binding ligand, template ion and porogen, respectively. The IIP nanoparticles were characterized using Fourier transformed infrared spectroscopy, thermogravimetric and differential thermal analysis, X-ray diffraction and scanning electron microscopy. A Box-Behnken design was used for optimization of sorption and desorption steps in UA-DSPE-IIP. In the sorption step: pH of solution, IIP amount (mg), sonication time for sorption (min); in the desorption step: concentration of eluent (mol l(-1)), volume of eluent (ml), sonication time (min) for desorption were investigated and optimized by Box-Behnken design. The optimum conditions for the method were: pH of solution, 7; sonication time for sorption, 7min; IIP amount, 17mg; type and concentration of eluent, HCl 1.5 mol l(-1); volume of eluent, 2ml; sonication time for desorption, 140s. Under the optimized conditions the limit of detection and relative standard deviation for the detection of silver ions using UA-DSPE-IIP were found to be 0.09 mu g l(-1) and <3%, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available