Tomography system for measurement of gas properties in combustion flow field

Journal

CHINESE JOURNAL OF AERONAUTICS
Volume 30, Issue 5, Pages 1697-1707

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cja.2017.08.004

Keywords

Absorption; Combustion diagnostics; Spectroscopy; Temperature; Tomographic image

Funding

  1. National Natural Science Foundation of China [61505263]

Ask authors/readers for more resources

This paper describes a self-designed fiber-coupled tomography system and its application in combustion diagnostics. The tomographic technique, which combines tunable diode laser spectroscopy and algebraic reconstruction technique, enables the simultaneous reconstruction of temperature and gas concentration with both spatial and temporal resolutions. The system measures a maximum diameter of 35 cm in a circular area with a minimum spatial resolution of 1 mm x 1 mm and temporal response of up to 1 kHz. Simulations validate the effects of the beam arrangement and discrete grid on reconstruction accuracy, and give the optimal beam arrangements. Experiments are made to demonstrate the tomography method, and systems are constructed in laboratory and on engineering test benches. (C) 2017 Production and hosting by Elsevier Ltd. on behalf of Chinese Society of Aeronautics and Astronautics. This is an open access article under the CC BY-NC-ND license.