4.7 Article

Optimization and modeling of preconcentration and determination of dyes based on ultrasound assisted-dispersive liquid-liquid microextraction coupled with derivative spectrophotometry

Journal

ULTRASONICS SONOCHEMISTRY
Volume 34, Issue -, Pages 27-36

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ultsonch.2016.05.013

Keywords

Azure B; Binary systems; Crystal violet; Derivative spectrophotometry; Dispersive liquid-liquid microextraction; Ultrasound-assisted

Funding

  1. Graduate School and Research Council of the Yasouj University

Ask authors/readers for more resources

Present study is based on describing an ultrasound-assisted dispersive liquid-liquid microextraction coupled with derivative spectrophotometry (UAS-DLLME-UV-vis) as useful technique for selective determination of crystal violet (CV) and azure b (Az-B). The significant factors like pH, extractor volume, disperser value and extraction time contribution and their numerical coefficient in quadratic model were calculated according to central composite design (CCD). According to desirability function (DF) as good criterion the best experimental conditions was adjusted and selected at pH of 7.0, 170 mu L of chloroform, 800 mu L, of ethanol that strongly mixed with the aqueous phase via 4 min sonication. Additionally, under study system was modeled by trained artificial neural networks (ANNs) as fitness function with acceptable error of MSE 2.97 x 10(-06) and 1.15 x 10(-05) with R-2: 0.9999 and 0.9997 for CV and Az-B, respectively. The optimum conditions by using genetic algorithm (GA) method was pH of 6.3, 160 mu L, of chloroform, 740 mu L of ethanol and 4.5 min sonication. Under above specified and optimize conditions, the predicted extraction percentage were 99.80 and 102.20% for CV and Az-B, respectively. The present UAS-DLLME-UV-vis procedure has minimum interference from other substances assign to the matrix, which candidate this method as good alternative to quantify under study dyes content with recoveries in the range of 86-100% for dyes. The detection limits were 2.043 ng mL(-1) and 1.72 ng mL(-1), and limits of quantitation were 6.81 ng mL(-1) and 5.727 ng mL(-1) for CV and Az-B, respectively. The proposed methodology was successfully applied for quantification of under study analytes at different media. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available