4.7 Article

Low-voltage electrochemically stimulated stir membrane liquid-liquid microextraction as a novel technique for the determination of methadone

Journal

TALANTA
Volume 168, Issue -, Pages 105-112

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2016.11.022

Keywords

Low-voltage electrochemically stimulated stir membrane liquid-liquid microextraction; Portable microextraction unit; Methadone; Biological samples; Liquid chromatography

Ask authors/readers for more resources

In the present work, for the first time, a new portable setup was designed, developed and presented for the extraction of methadone, as a basic drug model from biological fluid samples using a low-voltage electrically stimulated stir membrane liquid liquid microextraction technique (LV-ESSM-LLME), followed by high-performance liquid chromatography with ultraviolet detection. This new approach combines the advantages of stir membrane liquid liquid microextraction and electrokinetic migration in the same unit under soft electrochemical conditions in a portable device, allowing for the isolation and preconcentration of the target analyte in a simple and efficient manner under three-phase mode. To investigate the influence of external stirring and the application of electrical potential as the driving force, a comparative study of all variables involved in the extraction process was carried out using the low-voltage electromembrane extraction (LV-EME) and LV-ESSM-LLME methods. Under soft electrokinetic migration conditions, methadone was transported from an acidic sample solution (pH 4.0), through the NPOE immobilized in the pores of the porous polypropylene sheet membrane, and into 25 mu L of 10 mmol L-1 HC1 acceptor solution with a stirring rate of 1000 rpm and 700 rpm after 15 min and 20 min for LV-ESSM-LLME and LV-EME, respectively. Under the optimized conditions, preconcentration factors in the range of 17-24 and 21.5-29 for LV-EME and LV-ESSM-LLME, respectively, were considered, and satisfactory repeatability (4.5 < [RSD] < 7.5) was obtained in different matrices. The obtained relative recoveries of the target analyte were in the range of 87-94% and 93-101% for LV-EME and LV-ESSM-LLME, respectively, which indicated the excellent capability of the developed methods to extract methadone from complex matrices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available