4.7 Article

Improvement in mechanical properties of titanium alloy (Ti-6Al-7Nb) subject to multiple laser shock peening

Journal

SURFACE & COATINGS TECHNOLOGY
Volume 327, Issue -, Pages 101-109

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.surfcoat.2017.08.009

Keywords

Laser shock peening; Ti-6Al-7Nb; Titanium alloys; Properties; Microstructure; Wear; Hardness

Funding

  1. EPSRC [13250017 (NSL4)]
  2. EPSRC [EP/G03088X/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/G03088X/1] Funding Source: researchfish

Ask authors/readers for more resources

This paper is focused on laser shock peening (LSP) of titanium alloy (Ti-6Al-7Nb) for the first-time. This was to improve upon the artificial implant failures caused by destitute wear resistance of titanium alloys. As such, millions of patients are suffering from osteoarthritis pain, which costs billions of pounds annually to end users as they either have to undergo a complete replacement of the particular implants or a second surgery subject to implant failures. Therefore, the effect of multiple impacts on the mechanical properties and sliding wear behaviour of Ti-6Al-7Nb subjected to LSP were investigated. Ti-6Al-7Nb has the advantage of biocompatibility as the material can be applicable for orthopaedic implants. It is critical to improve the mechanical properties and wear resistance. LSP is one of the most effective methods to improve mechanical properties. Thus, in this study X-ray diffraction (XRD); Scanning Electron Microscope (SEM); surface roughness using 3-D profiling; microhardness using Vickers indentation method; and sliding wear with a tribometer were employed to measure the effect of Ti-6Al-7Nb alloy subjected LSP. It was found that the microhardness of Ti-6Al-7Nb alloy can be effectively improved from 290 HV30 to 369 HV30. In addition, the average the grain size was measured to be 10 pm and showed a reduction of 67%. The surface roughness was increased after multiple LSP from 0.15 pm to 0.52 pm. However, the wear resistance was improved by 44% after multiple LSP. The findings from this work will contribute towards extending the services time of orthopaedic implants and help patients undergo reduced number of surgeries. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available