4.7 Article

A colorimetric iron sensor based on the partition of phenanthroline complexes into polymeric hydrogels. Combinatorial synthesis and high throughput screening of the hydrogel matrix

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 241, Issue -, Pages 19-32

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2016.10.013

Keywords

Combinatorial chemistry; Iron; Hydrogel; Ligands; Colorimetric; Sensor; Water quality

Funding

  1. PRIS Nanopymes (EU-MCTIP(AR))
  2. FAN
  3. CONICET (PIP)
  4. SPU (Programa Amilcar Herrera)
  5. PDTS-CIN-CONICET
  6. SeCyT-UNRC (PPI- Programa Nanomateriales)
  7. EU [318903]

Ask authors/readers for more resources

A combinatorial library of hydrogels is produced by radical polymerization and tested for retention of iron (II) complexes, using a simple colorimetric high throughput screening (HTS). Six acrylamide monomers are used to produce a library of 21 cross-linked hydrogel matrixes. The swelling of all hydrogels is determined and related with the structure of each monomer unit present. The HTS shows that some materials are able to retain the tris(phenanthroline)iron(II) (Fe(Phen)(3)(2+)) complex. The partition coefficient of Fe(H2O)(6)(2+) and Fe(Phen)(3)(2+) in all hydrogels is determined by UV-vis spectrophotometry and related with the presence of anionic (e.g. -SO3-, hydrophobic (e.g. isopropyl) and hydrophilic (e.g. -NH2 of acrylamide) groups. Hydrogels with sulfonic (-SO3-) groups show large values of partition coefficients of Fe2+ into the hydrogel (>500). Based on the data and HTS, poly(acrylamide-co-50%(2-acrylamido-2-methylpropansulfonic acid)) (PAAm-co-50%AMPS) is selected to build a colorimetric sensor. Since the phenanthroline could be released from the hydrogel, bathophenanthroline (BPhen) which is not released is used as ligand. The hydrogel is loaded with BPhen and exposed to Fe2+ in water. The visual detection of color gives a detection limit of 0.1 ppm. Little interference of different common ions is found. A special set-up is made which allows spectrophotometric measurement of the complex inside the gel. The detection limit is found to be of ca. 0.01 ppm by spectrophotometry. Using the sensor, the iron content in milk is measured directly demonstrating the use of the sensor to measure free iron in opaque liquids where solution spectrophotometry is not effective without complex sample pretreatments. The non-covalent retention of ligands and complexes inside polymeric hydrogels seems to be a suitable method for building specific ion sensors. (C) 2016 Elsevier BM. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available