4.7 Article

Design of a piezoelectric pump with dual vibrators

Journal

SENSORS AND ACTUATORS A-PHYSICAL
Volume 257, Issue -, Pages 165-172

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2017.02.001

Keywords

Piezoelectric pump with dual vibrators; Optimization experiment; Check valve

Funding

  1. National Natural Science Foundation of China [51405189, 81171481]
  2. China Postdoctoral Science Foundation [2014M551195]
  3. Graduate Innovation Fund of Jilin University [2016072]

Ask authors/readers for more resources

The structures and working principles of a piezoelectric pump with dual vibrators are described in this paper. The output performance of the pump was analyses under different working modes. The experimental results demonstrate that changing the driving strategy can vary the performance. When the driving voltage is 60 V at 160 Hz, the maximum output pressure of the pump in the asynchronous mode is 2.18 kPa. The performance of the upper actuator working alone is better than the lower actuator working alone, and the maximum output pressure in this case is 1.3 kPa. Taking the piezoelectric pump with a single vibrator as a typical example, an optimal design method has been applied on the check valves. The performance of the pump with wheel valves is better than that with cantilever valves; the optimum thickness of the check valves is 0.188 mm. (C) 2017 Published by Elsevier B.V.