4.4 Article Proceedings Paper

A High Fundamental Frequency (HFF)-based QCM Immunosensor for Tuberculosis Detection

Journal

CURRENT TOPICS IN MEDICINAL CHEMISTRY
Volume 17, Issue 14, Pages 1623-1630

Publisher

BENTHAM SCIENCE PUBL LTD
DOI: 10.2174/1568026617666161104105210

Keywords

Tuberculosis; 38 kDa Biomarker; Monoclonal Antibody; ELISA; High Fundamental Frequency (HFF); Piezoelectric Immunosensor

Funding

  1. COLCIENCIAS (Colombia) [13335212865]
  2. AWSensors (Valencia, Spain)

Ask authors/readers for more resources

Background: Tuberculosis, one of the oldest diseases affecting human beings, is still considered as a world public health problem by the World Health Organization. Method & Material: Therefore, there is a need for new and more powerful analytical methods for early illness diagnosis. With this idea in mind, the development of a High Fundamental Frequency (HFF) piezoelectric immunosensor for the sensitive detection of tuberculosis was undertaken. A 38 kDa protein secreted by Mycobacterium tuberculosis was first selected as the target biomarker. Then, specific monoclonal antibodies (MAbs) were obtained. Myc-31 MAb, which showed the highest affinity to the analyte, was employed to set up a reference enzyme-linked immunosorbent assay (ELISA) with a limit of detection of 14 ng mL (-1) of 38 kDa antigen. Results & Discussion: For the development of the HFF piezoelectric immunosensor, 100 MHz quartz crystals were used as transducer elements. The gold electrode surface was functionalized by covalent immobilization of the target biomarker through mixed self-assembled monolayers (mSAM) of carboxylic alkane thiols. A competitive immunoassay based on Myc-31 MAb was integrated with the transducer as sensing bio-recognition event. Reliable assay signals were obtained using low concentrations of antigen for functionalization and MAb for the competitive immunoassay. Under optimized conditions, the HFF immunosensor calibration curve for 38 kDa determination showed a limit of detection as low as 11 ng mL (-1) of the biomarker. The high detectability attained by this immunosensor, in the picomolar range, makes it a promising tool for the easy, direct and sensitive detection of the tuberculosis biomarker in biological fluids such as sputum.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available