Ask authors/readers for more resources

BACKGROUND The heart ejects in the central elastic arteries. No previous study in workers described the diurnal profile of central blood pressure (BP) or addressed the question whether electrocardiogram (ECG) indexes are more closely associated with central than peripheral BP. METHODS In 177 men (mean age, 29.1 years), we compared the associations of ECG indexes with brachial and central ambulatory BP, measured over 24 hours by the validated oscillometric Mobil-O-Graph 24h PWA monitor. RESULTS From wakefulness to sleep, as documented by diaries, systolic/diastolic BP decreased by 11.7/13.1 mm Hg peripherally and 9.3/13.6 mm Hg centrally, whereas central pulse pressure (PP) increased by 4.3 mm Hg (P < 0.0001). Over 24 hours and the awake and asleep periods, the peripheral-minus-central differences in systolic/diastolic BPs averaged 11.8/-1.6, 12.7/-1.8, and 10.3/-1.2 mm Hg, respectively (P < 0.0001). Cornell voltage and index averaged 1.18 mV and 114.8 mV.ms. Per 1-SD increment in systolic/diastolic BP, the Cornell voltages were 0.104/0.086 mV and 0.082/0.105 mV higher in relation to brachial 24-hour and asleep BP and 0.088/0.90 mV and 0.087/0.107 mV higher in relation to central BP. The corresponding estimates for the Cornell indexes were 9.6/8.6 and 8.2/10.5 mV.ms peripherally and 8.6/8.9 and 8.8/10.7 mV.ms centrally. The regression slopes (P = 0.067) and correlation coefficients (P = 0.088) were similar for brachial and central BP. Associations of ECG measurements with awake BP and PP were not significant. CONCLUSIONS Peripheral and central BPs run in parallel throughout the day and are similarly associated with the Cornell voltage and index.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available