4.8 Review

Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA

Journal

RENEWABLE & SUSTAINABLE ENERGY REVIEWS
Volume 80, Issue -, Pages 1031-1042

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.rser.2017.05.216

Keywords

HFC-32; HFO mixtures; Two-phase flow; Energy performance; Climate change; Vapour compression system

Funding

  1. Swedish Energy Agency under the EFFSYS EXPAND P08 research program
  2. Spanish Ministry of Education, Culture, and Sport through Ayudas complementarias para beneficiarios de ayudas (FPU): Estancias Breves. Convocatoria [EST15/00154]

Ask authors/readers for more resources

Because air conditioning and heat pump systems contribute greatly to greenhouse gas emissions, equipment with both lower global warming potential (GWP) working fluids and a higher level of performance should be used. R32 (difluoromethane) has been proposed to substitute R410A, particularly in residential air conditioning (RAC) systems. This study collected the most relevant and recent researches into R32 as a refrigerant so as to assess its viability in RAC systems in both Europe and the USA, as compared to R410A and other lower GWP RAC alternatives. The R32 value of GWP is 677, which is below the F-gas regulation limit in RAC equipment (750). According to ASHRAE standard 34, R32 is less flammable than hydrocarbons, and the amount of charge permitted for R32 is above the necessary level in RAC equipment. It can be concluded that R32 has significantly good heat transfer characteristics and a level of performance that make it acceptable at low condensing temperatures, thereby avoiding overly high compressor discharge temperatures. Its performance is very similar to that of R410A across the entire operating range, and it is therefore believed that R32 will be utilized in RAC systems in the remaining countries that prioritize lower GWP fluids but are less strict in their security regulations. To replace R410A under extreme conditions, some system modifications can be conducted, or R32 mixtures with hydrofluoroolefins (HFOs) can be used. Such mixtures achieve a lower performance than R32, but are acceptable replacements when considering their lower GWP compared to that of R32, and similar level of flammability. Finally, other (R32-based) alternative mixtures have also been developed and their behaviours studied under a wide range of operating conditions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available