4.4 Article

Simultaneous determination of volatile organic compounds with a wide range of polarities in urine by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry

Journal

RAPID COMMUNICATIONS IN MASS SPECTROMETRY
Volume 31, Issue 7, Pages 613-622

Publisher

WILEY
DOI: 10.1002/rcm.7827

Keywords

-

Funding

  1. Korea Research Institute of Chemical Technology (KRICT)
  2. [KK1606-A00]

Ask authors/readers for more resources

RationaleVolatile organic compounds (VOCs) are ubiquitous environmental pollutants that have a high vapor pressure at room temperature. Some VOCs have been classified as carcinogenic to humans by the International Agency for Research on Cancer (IARC), because they can bind to DNA and cause cell mutations. Therefore, monitoring of VOCs in human urine is very important to evaluate the correlation between exposure to VOCs and human disease. MethodsWe have developed an improved analytical method for the simultaneous determination of VOCs with a wide range of polarities in human urine samples by headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography/mass spectrometry (GC/MS). In the improved method, a bi-polar carboxen-polydimethylsiloxane (CAR/PDMS) fiber was used for the optimized extraction of 15 VOCs with a wide range of polarities, including benzene, toluene, ethylbenzene, xylenes (BTEX), alkylbenzenes, cresols, and naphthalene, in human urine samples. Extracted VOCs from the human urine were effectively separated by GC using a mid-polarity column (DB-35, 35% phenylmethylpolysiloxane) and monitored by MS using extracted ion monitoring (EIM) mode. ResultsUnder the optimized method, the linearity of the calibration curves was greater than 0.993. The limits of detection (LODs) at a signal-to-noise (S/N) ratio of 3 were 0.3-0.6ng/mL. The coefficients of variation were in the range of 0.1-9.7% for within-day variation and 0.2-14.2% for day-to-day variation. ConclusionsThe method was shown to be rapid and simple for the simultaneous determination of VOCs with a wide range of polarities in human urine and it could be applied to monitoring and to biomedical investigations to check exposure to VOCs. Copyright (c) 2017 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available