Journal
RADIOCHIMICA ACTA
Volume 105, Issue 7, Pages 577-581Publisher
WALTER DE GRUYTER GMBH
DOI: 10.1515/ract-2016-2692
Keywords
Capacitors; radiation effects; dosimetry; dose; frequency
Ask authors/readers for more resources
In this experimental work, the effect of gamma irradiation on the capacitance and impedance of some commercial capacitors namely electrolytic, MKP, and MKT capacitors in different radiation doses up to 120 kGy and a wide range of frequencies between 42 Hz and 5 MHz were studied. Results showed that the capacitances of the electrolytic capacitors exhibited a linear decrease by increasing the radiation dose and frequencies, which can be used for high dosimetry purposes, but non-ceramic capacitors as MKP and MKT showed much higher radiation resistance, particularly for the frequencies less than similar to 1 MHz.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended