4.3 Article

Evaluation of gamma radiation response of electrolyte, MKP and MKT capacitors in various frequencies

Journal

RADIOCHIMICA ACTA
Volume 105, Issue 7, Pages 577-581

Publisher

WALTER DE GRUYTER GMBH
DOI: 10.1515/ract-2016-2692

Keywords

Capacitors; radiation effects; dosimetry; dose; frequency

Ask authors/readers for more resources

In this experimental work, the effect of gamma irradiation on the capacitance and impedance of some commercial capacitors namely electrolytic, MKP, and MKT capacitors in different radiation doses up to 120 kGy and a wide range of frequencies between 42 Hz and 5 MHz were studied. Results showed that the capacitances of the electrolytic capacitors exhibited a linear decrease by increasing the radiation dose and frequencies, which can be used for high dosimetry purposes, but non-ceramic capacitors as MKP and MKT showed much higher radiation resistance, particularly for the frequencies less than similar to 1 MHz.