4.2 Article

Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/0954411916688500

Keywords

Rotary ultrasonic bone drilling; conventional bone drilling; temperature; thermal necrosis; osteocytes; bone

Funding

  1. EPSRC-DST project Modelling of Advanced Materials for Simulation of Transformative Manufacturing Process''

Ask authors/readers for more resources

Bone drilling is common in orthopedic procedures and the heat produced during conventional experimental drilling often exceeds critical temperature of 47 degrees C and induces thermal osteonecrosis. The osteonecrosis may be the reason for impaired healing, early loosening and implant failure. This study was undertaken to control the temperature rise by interrupted cutting and reduced friction effects at the interface of drill tool and the bone surface. In this work, rotary ultrasonic drilling technique with diamond abrasive particles coated on the hollow drill tool without any internal or external cooling assistance was used. Experiments were performed at room temperature on the mid-diaphysis sections of fresh pig bones, which were harvested immediately after sacrifice of the animal. Both rotary ultrasonic drilling on bone and conventional surgical drilling on bone were performed in a five set of experiments on each process using identical constant process parameters. The maximum temperature of each trial was recorded by K-type thermocouple device. Ethylenediaminetetraacetic acid decalcification was done for microscopic examination of bone. In this comparative procedure, rotary ultrasonic drilling on bone produced much lower temperature, that is, 40.2 degrees C +/- 60.4 degrees C and 40.3 degrees C +/- 60.2 degrees C as compared to that of conventional surgical drilling on bone, that is, 74.9 degrees C +/- 60.8 degrees C and 74.9 degrees C +/- 60.6 degrees C with respect to thermocouples fixed at first and second position, respectively. The conventional surgical drilling on bone specimens revealed gross tissue burn, microscopic evidence of thermal osteonecrosis and tissue injury in the form of cracks due to the generated force during drilling. But our novel technique showed no such features. Rotary ultrasonic drilling on bone technique is robust and superior to other methods for drilling as it induces no thermal osteonecrosis and does not damage the bone by generating undue forces during drilling.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available