4.7 Article

Testing and finite element analysis of reinforced concrete column footings failing by punching shear

Journal

ENGINEERING STRUCTURES
Volume 92, Issue -, Pages 1-14

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2015.02.027

Keywords

Reinforced concrete; Column footing; Punching; Test; FEA; ANSYS

Funding

  1. Ministry of Science and Technological Research of Republic of Serbia [TR 36028, TR 36016]

Ask authors/readers for more resources

Finite element analysis (FEA) and engineering software is increasingly used in modelling of different structures and in analyzing their behaviour. The subject of this paper was an analysis of behaviour of reinforced concrete column footing laid on deformable subgrade and loaded by concentrated load until failure. The modelling and 3D nonlinear analysis were implemented by applying finite element method (FEM) and using software package ANSYS 14.5. Field test data were used for calibration of the FE model and validation of the adopted parameters for all materials. The comparison of the field test results and FEA results showed good agreement, but also revealed some questions regarding FEA, and especially concrete crushing. (C) 2015 Elsevier Ltd, All rights reserved.