4.7 Article

Strength, stiffness, resonance and the design of offshore wind turbine monopiles

Journal

ENGINEERING STRUCTURES
Volume 100, Issue -, Pages 332-341

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2015.06.021

Keywords

Offshore wind turbine; Monopile; Strength; Stiffness; Resonance avoidance; Operational; Extreme

Funding

  1. US National Science Foundation [CMMI-1234560, CMMI-1234656]
  2. Massachusetts Clean Energy Center
  3. Div Of Civil, Mechanical, & Manufact Inn
  4. Directorate For Engineering [1234560] Funding Source: National Science Foundation

Ask authors/readers for more resources

A monopile supporting an offshore wind turbine (OWT) is currently designed for both strength and stiffness. Regarding strength, the monopile is designed to have sufficient capacity to withstand demands under both 50-year operational conditions, when the rotor is spinning and blades are oriented to optimize power generation, and 50-year extreme conditions, when the rotor is parked and the blades feathered to minimize aerodynamic loads. Regarding stiffness, the monopile is designed to have sufficient stiffness such that the first structural frequency of the OWT falls between the 1P and 3P frequencies (rotation frequency and blade passing frequency for a three-bladed turbine). For six case studies, including three sites along the U.S. Atlantic coast and two mudline conditions (fixed and compliant), this paper delineates the conditions under which stiffness and strength govern the design of the monopile. This distinction has important implications for the overall risk profile of an OWT, as monopiles controlled by stiffness will have more reserve capacity than monopiles controlled by strength. The six case studies are intended to consider a range of water depths, metocean environments and mudline conditions that is representative of conditions suitable for installing OWTs supported by monopiles along the U.S. Atlantic coast. The monopile designs are controlled by stiffness for two of the six cases studies and, for these two cases, a modest (6-8%) reduction in monopile area (and mass) could be achieved if dynamic design requirements were achieved through means other than increasing monopile stiffness. Monopile designs for the remaining four cases are controlled by operational moment demands. (C) 2015 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available