4.6 Article

High performance refractive index sensor based on low Q-factor ring resonators and FFT processing of wavelength scanning data

Journal

OPTICS EXPRESS
Volume 25, Issue 7, Pages 7483-7495

Publisher

OPTICAL SOC AMER
DOI: 10.1364/OE.25.007483

Keywords

-

Categories

Funding

  1. European Commissioned [611528]

Ask authors/readers for more resources

We extend our previous simulation study and we present experimental results regarding our Fast Fourier Transform method for the calculation of the resonance shifts in biosensors based on micro-ring resonators (MRRs). For the simulation study, we use a system model with a tunable laser at 850 nm, an MRR with 1.5 center dot 10(4) quality factor, and a detection system with 50 dB maximum signal-to-noise ratio, and investigate the impact on the system performance of factors like the number of the resonance peaks inside the scanning window, the wavelength dependence of the laser power, and the asymmetry of the transfer functions of the MRRs. We find that the performance is improved by a factor of 2 when we go from single-to four-peak transfer functions, and that the impact of the wavelength dependence of the laser power is very low. We also find that the presence of asymmetries can lead to strong discontinuities of the transfer functions at the edges of the scanning window and can significantly increase the measurement errors, making necessary the use of techniques for their elimination. Using these conclusions, we build a system with sensing MRRs on TriPleX platform, and we experimentally validate our method using sucrose solutions with different concentrations. Involving techniques in order to exclude the noise originating from the microfluidic system, we achieve a wavelength resolution close to 0.08 pm, when the system operates with 0.5 pm scanning step. In combination with the sensitivity of the MRRs, which is measured to be equal to 93.7 nm/RIU, this wavelength resolution indicates the possibility for a limit of detection close to 8.5 center dot 10(-7) RIU, which represents to the best of our knowledge a record performance for this type of optical sensors and this level of scanning steps. (C) 2017 Optical Society of America

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available