3.8 Proceedings Paper

Concrete propensity to fire spalling: testing and observations

Publisher

E D P SCIENCES
DOI: 10.1051/matecconf/201816302004

Keywords

-

Funding

  1. Polish National Science Centre [N N506 045040]

Ask authors/readers for more resources

This article presents results of fire spalling tests on small concrete slabs and studies of material parameters that may increase its occurrence. Experimental techniques enabling to study and determination of material features are presented and discussed. Experimental studies on spalling behaviour of elements were carried out on seven different concrete mixes with constant content of cement paste and mortar. Research aimed at determining influence of the following parameters: w/c ratio (0.30; 0.45; 0.60), cement type (CEM I, CEM III) and type of aggregates (riverbed gravel, granite, basalt) on fire concrete spalling. Paper discusses also the influence of cold rim that forms while testing slab-like element is subjected to one-side heating.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available