4.4 Article

The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation

Journal

JACC-CLINICAL ELECTROPHYSIOLOGY
Volume 5, Issue 2, Pages 199-208

Publisher

ELSEVIER
DOI: 10.1016/j.jacep.2018.10.006

Keywords

atrial fibrillation; iECG screening; mobile ECG; photoplethysmography; screening; smartwatch

Funding

  1. University Hospital Basel

Ask authors/readers for more resources

OBJECTIVES The WATCH AF (SmartWATCHes for Detection of Atrial Fibrillation) trial compared the diagnostic accuracy to detect atrial fibrillation (AF) by a smartwatch-based algorithm using photoplethysmographic (PPG) signals with cardiologists' diagnosis by electrocardiography (ECG). BACKGROUND Timely detection of AF is crucial for stroke prevention. METHODS In this prospective, 2-center, case-control trial, a PPG pulse wave recording using a commercially available smartwatch was obtained along with Internet-enabled mobile ECG in 672 hospitalized subjects. PPG recordings were analyzed by a novel automated algorithm. Cardiologists' diagnoses were available for 650 subjects, although 142 (21.8%) datasets were not suitable for PPG analysis, among them 101 (15.1%) that were also not interpretable by the automated Internet-enabled mobile ECG algorithm, resulting in a sample size of 508 subjects (mean age 76.4 years, 225 women, 237 with AF) for the main analyses. RESULTS For the PPG algorithm, we found a sensitivity of 93.7% (95% confidence interval [CI]: 89.8% to 96.4%), a specificity of 98.2% (95% CI: 95.8% to 99.4%), and 96.1% accuracy (95% CI: 94.0% to 97.5%) to detect AF. CONCLUSIONS The results of the WATCH AF trial suggest that detection of AF using a commercially available smartwatch is in principle feasible, with very high diagnostic accuracy. Applicability of the tested algorithm is currently limited by a high dropout rate as a result of insufficient signal quality. Thus, achieving sufficient signal quality remains challenging, but real-time signal quality checks are expected to improve signal quality. Whether smartwatches may be useful complementary tools for convenient long-term AF screening in selected at-risk patients must be evaluated in larger population-based samples. (C) 2019 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available