4.7 Article

Determination of state of charge of lead-acid battery by EIS

Journal

JOURNAL OF ENERGY STORAGE
Volume 21, Issue -, Pages 581-585

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.est.2018.12.020

Keywords

Lead-acid batteries; Impedance; Z-modulus; Phase angle; State of charge

Categories

Funding

  1. Centre for Research and Utilization of Renewable Energy (CVVOZE)
  2. Ministry of Education, Youth and Sports of the Czech Republic under NPU I programme [LO1210]

Ask authors/readers for more resources

The paper explores state of charge (SoC) determination of lead-acid battery cell by electrochemical impedance spectroscopy (EIS) method. Lead-acid cell was explored during intermittent discharge and intermittent charge. Nyquist diagram, open circuit voltage, Z-modulus and the phase angle of the cell for frequencies 853 Hz, 5.37 Hz and 351 mHz were used for the state of charge determination.