4.6 Article

Selective red-emission detection for mercuric ions in aqueous solution and cells using a fluorescent probe based on an unnatural peptide receptor

Journal

ORGANIC & BIOMOLECULAR CHEMISTRY
Volume 17, Issue 14, Pages 3590-3598

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c8ob03224f

Keywords

-

Funding

  1. National Research Foundation of Korea [2017R1A2B2006897]
  2. Korea Environmental Industry and Technology Institute [2015000540007]
  3. National Research Foundation of Korea [2017R1A2B2006897] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The selective ratiometric red-emission detection of Hg2+ ions in aqueous buffered solutions and live cells is still a significant challenge. In the present study, we synthesized a fluorescent probe (1) based on an unnatural peptide receptor containing sulfonamide groups with an aggregation-induced emission and twisted internal charge transfer (TICT)-active fluorophore, cyanostilbene. 1 exhibited a highly selective ratiometric response to Hg2+ among 14 metal ions tested by ratiometric red-emission at 600 nm, with a clear isoemissive point in purely aqueous solution containing 1% DMSO. The ratiometric response for Hg2+ ions was complete within 3 min and the ratiometric responses induced by Hg2+ ions did not suffer considerable interference from the other metal ions. The ratiometric response was complete for less than 7 M Hg2+ and 1 had a potent binding affinity (7.42 x 10(-6) M, R-2 = 0.98) for Hg2+ and a nanomolar detection limit. 1 detected Hg2+ ions by ratiometric responses in aqueous buffered solutions over a wide range of pH (5.5-11.5). Binding mode studies using TEM, NMR, IR, and a mass spectrometer revealed that the sulfonamide groups of the unnatural peptide receptor played an important role in the complexation of Hg2+ and in the complexation-induced nano-sized aggregates, which resulted in a significant increase in emissions at 600 nm and a decrease in emissions at 535 nm. 1 quantified micro-molar concentrations (0-6 M) of Hg2+ in tap water and groundwater by ratiometric detection. Furthermore, 1 passed through the lipid membranes of live cells and detected intracellular Hg2+ ions at 2 M by a ratiometric red-emission change.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available