4.5 Article

Evaluating biases in filter-based aerosol absorption measurements using photoacoustic spectroscopy

Journal

ATMOSPHERIC MEASUREMENT TECHNIQUES
Volume 12, Issue 6, Pages 3417-3434

Publisher

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/amt-12-3417-2019

Keywords

-

Funding

  1. Natural Environment Research Council [NE/L013797/1, NE/L013584/1, NE/N015835/1]
  2. Natural Environment Research Council/Met Office [640052003]
  3. Research Council of Norway
  4. Royal Society of Chemistry (Analytical Chemistry Trust Fund, Tom West Fellowship)
  5. NERC [ncas10015, NE/L013797/1, NE/N015835/1, NE/L013584/1] Funding Source: UKRI

Ask authors/readers for more resources

Biases in absorption coefficients measured using a filter-based absorption photometer (Tricolor Absorption Photometer, or TAP) at wavelengths of 467, 528 and 652 nm are evaluated by comparing to measurements made using photoacoustic spectroscopy (PAS). We report comparisons for ambient sampling covering a range of aerosol types including urban, fresh biomass burning and aged biomass burning. Data are also used to evaluate the performance of three different TAP correction schemes. We found that photoacoustic and filter-based measurements were well correlated, but filter-based measurements generally overestimated absorption by up to 45 %. Biases varied with wavelength and depended on the correction scheme applied. Optimal agreement to PAS data was achieved by processing the filter-based measurements using the recently developed correction scheme of Muller et al. (2014), which consistently reduced biases to 0 %-18% at all wavelengths. The biases were found to be a function of the ratio of organic aerosol mass to light-absorbing carbon mass, although applying the Muller et al. (2014) correction scheme to filter-based absorption measurements reduced the biases and the strength of this correlation significantly. Filter-based absorption measurement biases led to aerosol single-scattering albedos that were biased low by values in the range 0.00-0.07 and absorption Angstrom exponents (AAEs) that were in error by +/- (0.03-0.54). The discrepancy between the filter-based and PAS absorption measurements is lower than reported in some earlier studies and points to a strong dependence of filter-based measurement accuracy on aerosol source type.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available