4.4 Article

Comparative study of cephalometric measurements using 3 imaging modalities

Journal

JOURNAL OF THE AMERICAN DENTAL ASSOCIATION
Volume 148, Issue 12, Pages 913-921

Publisher

AMER DENTAL ASSOC
DOI: 10.1016/j.adaj.2017.07.030

Keywords

-

Funding

  1. National Natural Science Foundation of China [81470712, 81670960]
  2. Natural Science Foundation of Jiangsu Province [BK20171123]
  3. Jiangsu Provincial Medical Youth Talent

Ask authors/readers for more resources

Background. The authors conducted a study to compare 2-dimensional (2D) lateral cephalometric radiography (LCR), 2D cone-beam computer tomographic (CBCT)-generated cephalogram and 3-dimensional (3D) CBCT for assessing cephalometric measurements. Methods. The authors took 2D LCR, 2D CBCT-generated cephalogram, and 3D CBCT images involving 60 participants. They obtained 11 angular and 11 linear measurements for all images. They used 1-way analysis of variance and the Fisher least significant difference test for statistical comparisons. The authors used Pearson correlation and Pearson chi(2) test to assess the relationship of these imaging modalities for vertical cephalometric analyses. Results. Significant differences existed between the 2D cephalograms (LCR and CBCT-generated cephalogram) and the 3D CBCT in 2 angular measurements (maxillary first incisor-nasion (N) point A [A] and mandibular first incisor-N point B (B) (P = .027 and P <. 001, respectively) and 5 linear measurements (N menton[Me]/sella gonion [Go], condylion [Co]A, Co gnathion, Go-Me and anterior nasal spine-posterior nasal spine) (P < .004). These measurement values with significant differences were generally greater (approximately 5 degrees for angular measurements and 10 millimeters for linear measurements) on the 3D CBCT scans than on the 2D cephalograms. No significant difference was found between the 2 2D cephalograms (P > .164). No significant difference was found among the 3 imaging modalities for the vertical cephalometric analyses (P > .466). Conclusions. Significant differences existed between the 2D cephalograms (LCR and CBCT-generated cephalogram) and the 3D CBCT scans in 2 angular and 5 linear measurements. The 2 2D cephalograms were similar for cephalometric measurements. The 3 imaging modalities had no significant difference for the vertical cephalometric analyses. CBCT might not add value for every orthodontic situation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available