4.7 Article

Transcatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses PARTNER 2 Valve-in-Valve Registry

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 69, Issue 18, Pages 2253-2262

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2017.02.057

Keywords

6-min walk test; aortic stenosis; mortality; registry; regurgitation

Funding

  1. Edwards Lifesciences
  2. St. Jude Medical
  3. Medtronic
  4. Boston Scientific
  5. Abbott Vascular
  6. Gore
  7. Siemens
  8. Cardiokinetix
  9. Mitraspan
  10. National Heart Lung Blood Institute [HL67025]

Ask authors/readers for more resources

BACKGROUND Early experience with transcatheter aortic valve replacement (TAVR) within failed bioprosthetic surgical aortic valves has shown that valve-in-valve (VIV) TAVR is a feasible therapeutic option with acceptable acute procedural results. OBJECTIVES The authors examined 30-day and 1-year outcomes in a large cohort of high-risk patients undergoing VIV TAVR. METHODS Patients with symptomatic degeneration of surgical aortic bioprostheses at high risk (>= 50% major morbidity or mortality) for reoperative surgery were prospectively enrolled in the multicenter PARTNER (Placement of Aortic Transcatheter Valves) 2 VIV trial and continued access registries. RESULTS Valve-in-valve procedures were performed in 365 patients (96 initial registry, 269 continued access patients). Mean age was 78.9 +/- 10.2 years, and mean Society of Thoracic Surgeons score was 9.1 +/- 4.7%. At 30 days, all-cause mortality was 2.7%, stroke was 2.7%, major vascular complication was 4.1%, conversion to surgery was 0.6%, coronary occlusion was 0.8%, and new pacemaker insertion was 1.9%. One-year all-cause mortality was 12.4%. Mortality fell from the initial registry to the subsequent continued access registry, both at 30 days (8.2% vs. 0.7%, respectively; p = 0.0001) and at 1 year (19.7% vs. 9.8%, respectively; p = 0.006). At 1 year, mean gradient was 17.6 mm Hg, and effective orifice area was 1.16 cm(2), with greater than mild paravalvular regurgitation of 1.9%. Left ventricular ejection fraction increased (50.6% to 54.2%), and mass index decreased (135.7 to 117.6 g/m(2)), with reductions in both mitral (34.9% vs. 12.7%) and tricuspid (31.8% vs. 21.2%) moderate or severe regurgitation (all p < 0.0001). Kansas City Cardiomyopathy Questionnaire score increased (mean: 43.1 to 77.0) and 6-min walk test distance results increased (mean: 163.6 to 252.3 m; both p < 0.0001). CONCLUSIONS In high-risk patients, TAVR for bioprosthetic aortic valve failure is associated with relatively low mortality and complication rates, improved hemodynamics, and excellent functional and quality-of-life outcomes at 1 year. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves [PARTNER II]; NCT01314313) (C) 2017 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available