4.6 Article

Simultaneous determination of pentoxifylline, metabolites M1 (lisofylline), M4 and M5, and caffeine in plasma and dried blood spots for pharmacokinetic studies in preterm infants and neonates

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 146, Issue -, Pages 302-313

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2017.08.030

Keywords

Pentoxifylline; Caffeine; Neonates; LC-MS/MS; Plasma; Dried blood spots

Funding

  1. Telethon-Perth Children's Hospital Research Fund, a initiative of the Channel 7 Telethon Trust
  2. Telethon-Perth Children's Hospital Research Fund, a initiative of the Western Australian Department of Health

Ask authors/readers for more resources

Advances in bioanalytical methods are facilitating micro-volume and dried blood spot (DBS) analysis of drugs in biological matrices for pharmacokinetic studies in children and neonates. We sought to develop a UPLC-MS/MS assay for simultaneous measurement of caffeine, pentoxifylline (PTX) and three metabolites of PTX in both plasma and DBS. Caffeine, PTX, the metabolites M1 (lisofylline), M4 and M5, and the internal standards (caffeine-d9 and PTX-d6) were separated using a Waters Aquity T3 UPLC C-18 column and gradient mobile phase (water methanol-formic acid). Retention times for caffeine, M5, M4, PTX and M1 were 1.6, 1.7, 1.9, 2.0 and 2.1 min, respectively, with a run time of 5 min. The precision (<= 10%) and accuracy (<= 15%) across the concentration range 0.1-50 mg/L for caffeine, PTX and the three metabolites in plasma and DBS were within accepted limits, as were the limits of quantification (100 mu g/L for caffeine and 10 a for PTX, M1, M4 and M5). Caffeine, PTX and the metabolites were stable in DBS for >34 days at room and refrigerated temperatures. Plasma and DBS samples were obtained from 24 preterm infants recruited into a clinical pharmacokinetic study of PTX. Paired analysis indicated that DBS concentrations were 9% lower than concurrent plasma concentrations for caffeine, 7% lower for PTX (consistent with the blood:plasma ratio) and 13% lower for Ml (lisofylline). The validated UPLC-MS/MS method is suitable for micro-volume plasma and DBS analysis of caffeine, PTX and its metabolites for pharmacokinetic studies in paediatric patients. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available