Journal
JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME
Volume 139, Issue 4, Pages -Publisher
ASME
DOI: 10.1115/1.4035771
Keywords
flexural failure; thick level ice; multiyear ice; sloping structure
Categories
Funding
- National Research Foundation
- Keppel Corporation
- National University of Singapore
Ask authors/readers for more resources
This paper investigates the breaking load of ice sheets up to 6m thick, against a sloping structure. The reference model by Croasdale, which the design code is based on, neglects the edge moment arising from the loading eccentricity, as well as a second-order bending effect induced by the axial loading in its formulation. In this paper, the model is reformulated to incorporate these effects into the governing equation, as well as to account for the occurrence of local crushing at the point of contact between the ice sheet and sloping structure. For thin ice, predictions from the modified model resemble closely those by Croasdale's model. As the ice thickness increases, however, significant deviations from the reference model can be observed. For thick ice, the terms omitted for brevity in the reference model have a significant influence, without which the breaking load is underestimated. It is furthermore demonstrated that against sloping structures, the dominant failure mode is that of flexural, except in very limiting cases where it switches to crushing.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available