4.4 Article

Efficacy of real-time continuous glucose monitoring on glycaemic control and glucose variability in type 1 diabetic patients treated with either insulin pumps or multiple insulin injection therapy: a randomized controlled crossover trial

Journal

DIABETES-METABOLISM RESEARCH AND REVIEWS
Volume 31, Issue 1, Pages 61-68

Publisher

WILEY
DOI: 10.1002/dmrr.2557

Keywords

SMBG; T1D; glucose variability; real-time CGM; CSII

Ask authors/readers for more resources

BackgroundThe aim of this study was to determine the efficacy of real-time continuous glucose monitoring in T1D patients treated with insulin pump therapy or multiple daily insulin therapy. MethodsTwenty adult patients (ten insulin pump therapy and ten multiple daily insulin) with poor glycaemic control (HbA(1c)>8.0%) were randomized into two groups for 6months: the continuous glucose monitoring arm (using real-time continuous glucose monitoring) and the SMBG arm. After 2 months of wash-out, the participants crossed over. The primary outcome was HbA(1c) reduction. The secondary outcomes were hypoglycaemia and hyperglycaemia risk assessment (area under the curve<70mg/dL/day and AUC>200mg/dL/day, respectively) and glucose variability. ResultsFourteen patients (eight multiple daily insulin, six insulin pump therapy) used continuous glucose monitoring appropriately (at least 40% of the time). In these patients, the improvement in glycaemic control was more evident during the real-time continuous glucose monitoring period (7.76%0.4 vs 8.54%+/- 0.4, p<0.05) than during the self-monitoring of blood glucose period (8.42%+/- 0.4 vs 8.56%+/- 0.5, p=0.2). Better results with continuous glucose monitoring were observed in patients using multiple daily insulin with greater improvement in both glycaemic control (7.71%+/- 0.2 vs 8.58%+/- 0.2, p<0.05) and glucose variability and with a marked reduction in the risk of both hypoglycaemia and hyperglycaemia. ConclusionsAppropriate use of real-time continuous glucose monitoring improved glycometabolic control in T1D patients. The effects of continuous glucose monitoring were more evident in patients under multiple daily insulin treatment, compared with insulin pump therapy. Glucose variability, in addition to glycaemic control, was improved in compliant diabetic patients. Copyright (c) 2014 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available