3.8 Proceedings Paper

RFID Tag Failure After Thermal Overstress

Publisher

IEEE
DOI: 10.1109/iirw47491.2019.8989885

Keywords

RFID; failure; thermal budget; temperature; mission profile

Funding

  1. INTERREG VA program of the European Union

Ask authors/readers for more resources

In this work the failure modes and mechanisms are investigated of a commercially available RFID tag, when it is exposed to extreme temperatures well beyond specifications. Both erroneous functioning and malfunctioning are observed after a thermal cycle exposing the tag to an elevated temperature in the 300-550 degrees C range. Void formation is the dominant failure, leading to a complete malfunction of the tag. Sporadically, the RFID tag returns a wrong identification code after extreme thermal cycling. This effect is caused by relatively weak bits flipping from 1 to 0 and seems consistent with existing retention models.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available