4.7 Article

Fabrication of reduced graphene oxide-magnetic nanocomposite (rGO-Fe3O4) as an electrochemical sensor for trace determination of As(III) in water resources

Journal

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
Volume 796, Issue -, Pages 33-42

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2017.04.061

Keywords

Arsenate; Electrochemical sensor; Magnetic nanoparticles; Graphene; Water

Funding

  1. Universiti Putra Malaysia (Grant Putra-IPS) [9490200]
  2. University of Malaya Research Grant UMRG [RP012B-14SUS]

Ask authors/readers for more resources

In this work, an electrochemical sensor has been developed for trace determination of As(III) in water resources using differential pulse anodic stripping voltammetry (DPASV), on the surface of screen printed electrode modified reduced graphene oxide-magnetic nanocomposite (rGO-Fe3O4/SPE). Field Emission Scanning Electron Microscopy (FESEM) and Transmission Electron Microscopy (TEM) showed a homogeneous distribution of Fe3O4 nanoparticles on GO sheets with an average size of 15.90 +/- 0.84 nm. Raman spectroscopy and Electrochemical Impedance Spectroscopy (EIS) studies demonstrate that while As(III) was reduced to As, during deposition step (-0.5 V, 300 s), GO nanosheets were electrochemically reduced to rGO to provide more sensitive and conductive substrate. Under optimized conditions, the anodic peak current was proportional to the As(III) concentration over a wide range of 2-300 mu g L-1, with a detection limit and quantitative limit of 0.10 and 0.33 mu g L-1 (S/N = 3) respectively. The proposed As(III) electrochemical sensor also exhibited a relative standard deviation of 3.2% for six replicate analysis of 50 mu g L-1 As(III). Stability test showed the sensor retained similar to 93% of its initial signal after 30 successive measurements and similar to 90% of its initial measurement after two weeks storage at room temperature. In addition, the fabricated sensor was successfully employed for determining the As(III) residue in several water samples including lake water, reverse osmosis drink water and mineral water. The results were in agreement with inductively coupled plasma mass spectrometry (ICP-MS) when compared.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available