4.2 Article

Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions

Journal

JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY
Volume 42, Issue 2, Pages 184-190

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RCT.0000000000000666

Keywords

iterative reconstruction; ASIR; MBIR; CT image quality; abdomen

Funding

  1. National Institute of Health/National Cancer Institute [P30CA016672]

Ask authors/readers for more resources

Objective The purpose of this study was to compare abdominopelvic computed tomography images reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) with model-based iterative reconstruction (Veo 3.0), ASIR, and filtered back projection (FBP). Methods and Materials Abdominopelvic computed tomography scans for 36 patients (26 males and 10 females) were reconstructed using FBP, ASIR (80%), Veo 3.0, and ASIR-V (30%, 60%, 90%). Mean SD patient age was 32 10 years with mean +/- SD body mass index of 26.9 +/- 4.4 kg/m(2). Images were reviewed by 2 independent readers in a blinded, randomized fashion. Hounsfield unit, noise, and contrast-to-noise ratio (CNR) values were calculated for each reconstruction algorithm for further comparison. Phantom evaluation of low-contrast detectability (LCD) and high-contrast resolution was performed. Results Adaptive statistical iterative reconstruction-V 30%, ASIR-V 60%, and ASIR 80% were generally superior qualitatively compared with ASIR-V 90%, Veo 3.0, and FBP (P < 0.05). Adaptive statistical iterative reconstruction-V 90% showed superior LCD and had the highest CNR in the liver, aorta, and, pancreas, measuring 7.32 +/- 3.22, 11.60 +/- 4.25, and 4.60 +/- 2.31, respectively, compared with the next best series of ASIR-V 60% with respective CNR values of 5.54 +/- 2.39, 8.78 +/- 3.15, and 3.49 +/- 1.77 (P <0.0001). Veo 3.0 and ASIR 80% had the best and worst spatial resolution, respectively. Conclusions Adaptive statistical iterative reconstruction-V 30% and ASIR-V 60% provided the best combination of qualitative and quantitative performance. Adaptive statistical iterative reconstruction 80% was equivalent qualitatively, but demonstrated inferior spatial resolution and LCD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available