4.5 Article

Monitoring a building made of CLT in Ljubljana

Journal

WOOD MATERIAL SCIENCE & ENGINEERING
Volume -, Issue -, Pages -

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/17480272.2020.1712740

Keywords

Wood; Norway spruce; monitoring; wood moisture content; relative humidity; temperature

Funding

  1. Slovenian Research Agency (Javna Agencija za Raziskovalno Dejavnost RS) [L4-7547, P4-0015]
  2. project: Wood and wood products over a lifetime (WOOLF) (Ministrstvo za Izobrazevanje, Znanost in Sport)
  3. [IC LES PST 0481-09]

Ask authors/readers for more resources

The importance of renewable and environmentally acceptable materials in the construction industry is increasing. Wood is one of the most important construction materials and its use in building applications has further expanded in recent decades, mainly due to the development of modern composites, firstly glue lam, OSB (Oriented Strand Board), LVL (Laminated Veneer Lumber) and a considerable breakthrough was later achieved with the development of cross-laminated timber. In order to enable even more extensive and reliable use of wood in outdoor applications, factors affecting a wood's service life need to be understood. It is well known that fungal degradation of wood is predominantly affected by temperature and wood moisture content. In order to elucidate the influence of these two factors, long-term monitoring of temperature, relative humidity and moisture content at the newly-built Annex of the Department of Wood Science and Technology was carried out. The Annex is designed from CLT composites and glue-lam beams and was finished in December 2015. The results clearly show that microclimatic conditions in the monitored building in the first years of use are far below the limit required for fungal decay or mould growth.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available