4.1 Article

The effect of unit, depth, and probe load on the reliability of muscle shear wave elastography: Variables affecting reliability of SWE

Journal

JOURNAL OF CLINICAL ULTRASOUND
Volume 46, Issue 2, Pages 108-115

Publisher

WILEY
DOI: 10.1002/jcu.22534

Keywords

elastography; muscles; reliability; ultrasound

Funding

  1. National Institute for Health Research (NIHR) Leeds Biomedical Research Centre
  2. National Institute for Health Research [NF-SI-0508-10299, RC-PG-0407-10054, NF-SI-0513-10139] Funding Source: researchfish
  3. Versus Arthritis [20639, 18475] Funding Source: researchfish

Ask authors/readers for more resources

PurposeThere is currently no standardized method for muscle shear wave elastography (SWE). The objective of this study was to investigate the effect of unit of measurement, depth, and probe load on the reliability of muscle SWE. MethodsThe vastus lateralis, biceps femoris, biceps brachii, and abductor digiti minimi muscles were scanned on 20 healthy participants. The SWE readings were measured in shear wave velocity (m/s) and Young's modulus (kPa). Three acquisitions of varying depths were acquired from vastus lateralis. Minimal probe load was compared with the use of a standoff gel layer. Three repeated measurements were acquired to assess reliability using intraclass correlations (ICC). ResultsThe mean elasticity varied across muscle groups and ranged from 1.54 m/s for biceps femoris to 2.55 m/s for abductor digiti minimi (difference=1.01 m/s [95% confidence interval, CI=0.92, 1.10]). Reporting readings in meters per second resulted in higher ICC of 0.83 (0.65, 0.93) in comparison to 0.77 (0.52, 0.90) for kilopascal for the vastus lateralis muscle only. Variance increased proportionally with depth reaching 0.17 (equivalent to 0.82 m/s) at 6 cm. Using a standoff gel decreased ICC to 0.63 (0.20, 0.84) despite similar mean elasticity readings to minimal probe load. ConclusionsDifferent acquisition and technical factors may significantly affect the reliability of SWE in skeletal muscles. Readings acquired in the unit of shear wave velocity (m/s) from depths less than 4 cm using a minimal probe load without a standoff gel yielded the best reliability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available