4.7 Article

An urban ecohydrological model to quantify the effect of vegetation on urban climate and hydrology (UT&C v1.0)

Journal

GEOSCIENTIFIC MODEL DEVELOPMENT
Volume 13, Issue 1, Pages 335-362

Publisher

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/gmd-13-335-2020

Keywords

-

Funding

  1. Future Cities Laboratory at the ETH Zurich [FI370074016]

Ask authors/readers for more resources

Increasing urbanization is likely to intensify the urban heat island effect, decrease outdoor thermal comfort, and enhance runoff generation in cities. Urban green spaces are often proposed as a mitigation strategy to counteract these adverse effects, and many recent developments of urban climate models focus on the inclusion of green and blue infrastructure to inform urban planning. However, many models still lack the ability to account for different plant types and oversimplify the interactions between the built environment, vegetation, and hydrology. In this study, we present an urban ecohydrological model, Urban Tethys-Chloris (UT&C), that combines principles of ecosystem modelling with an urban canopy scheme accounting for the biophysical and ecophysiological characteristics of roof vegetation, ground vegetation, and urban trees. UT&C is a fully coupled energy and water balance model that calculates 2 m air temperature, 2m humidity, and surface temperatures based on the infinite urban canyon approach. It further calculates the urban hydrological fluxes in the absence of snow, including transpiration as a function of plant photosynthesis. Hence, UT&C accounts for the effects of different plant types on the urban climate and hydrology, as well as the effects of the urban environment on plant well-being and performance. UT&C performs well when compared against energy flux measurements of eddy-covariance towers located in three cities in different climates (Singapore, Melbourne, and Phoenix). A sensitivity analysis, performed as a proof of concept for the city of Singapore, shows a mean decrease in 2m air temperature of 1.1 degrees C for fully grass-covered ground, 0.2 degrees C for high values of leaf area index (LAI), and 0.3 degrees C for high values of V-c,V-max (an expression of photosynthetic capacity). These reductions in temperature were combined with a simultaneous increase in relative humidity by 6.5 %, 2.1 %, and 1.6 %, for fully grass-covered ground, high values of LAI, and high values of V-c,V-max,V- respectively. Furthermore, the increase of pervious vegetated ground is able to significantly reduce surface runoff.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available