4.6 Article

Poly(glycidyl methacrylate) nanoparticle-coated capillary with oriented antibody immobilization for immunoaffinity in-tube solid phase microextraction: Preparation and characterization

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1509, Issue -, Pages 1-8

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2017.06.023

Keywords

Oriented antibody immobilization; In-tube solid phase microextraction; Immunoaffinity; Nanoparticle-coated capillary

Funding

  1. National Natural Science Foundation of China [81303267, 81402889, 21605114]
  2. Tianjin Natural Science Foundation [14JCY-BJC24300, 16JCQNJC05500]
  3. open foundation of Key laboratory of Opto-electronic Information Technology, Ministry of Education (Tianjin University) [2017KFKT002]

Ask authors/readers for more resources

A combination between modification with nanoparticles (NP) and oriented antibody immobilization (OAI) on the inner face of capillary was for the first time developed for immunoaffinity in-tube solid phase microextraction (SPME) to promise high antigen extraction capacity. beta(2)-microglobin (beta(2)MG) and cystatin C (Cys-C) were selected as model antigens. Poly(glycidyl methacrylate) (PGMA) NPs were chemically immobilized onto the capillary by a ring-opening reaction. Antibodies for beta(2) MG and Cys-C were immobilized on the NPs through OAI. Scanning electron micrograph of the OAI capillary clearly showed that the PGMA NPs were coated onto the inner surface of capillary in a dense monolayer. In addition, random antibody immobilized (RAI) capillaries and OAI capillaries without NP were also prepared as controls. The extraction capacities of OAI capillaries were 2.02 and 2.18 mg m(-1) for beta(2)MG and Cys-C, and were about 5 and 6 times as many as RAI capillaries and OAI capillaries without NP, respectively. The resultant capillaries were used as in-tube SPME materials to enrich beta(2)MG and Cys-C for particle-enhanced turbidimetric immunoassay. When using 1.0 mg L-1 standard solutions, the recoveries of OAI capillaries, RAI capillaries and OAI capillaries without NP were 103.6% and 96.8%, 48.5% and 31.5%, and 24.2% and 25.7% for beta(2)MG and Cys-C, respectively. Furthermore, the method quantitation limit by OAI capillaries was 5 and 10 times lower than that by RAI capillaries and OAI capillaries without NP, respectively. This result indicated that the NP-coated capillaries with OAI are more suitable for using as immunoaffinity in-tube SPME materials than that with RAI. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available